Automatic calculate K value and equipped with MES interface
Fully automatic calibration tooling, ensuring test accuracy of voltage and internal resistance
Wide compatibility range, modularized & flexible design, easy to changeover
Test mechanism and unique wiring design avoid interference, no eddy current
Basic Parameters
Machine Capacity:≥16PPM
Voltage Testing Accuracy:a) Voltage range: DC 0~10000mV b) Test accuracy: ±0.0020%rdg. ±12µm c) Prismatic cell voltage testing accuracy: ± 0.2mV
Internal Resistance Testing Accuracy:a) Range of internal resistance: 0µΩ~3KΩ b) Testing accuracy: ±(0.5%rdg.+10dgt.) c) Testing frequency: 1KHz±0.2Hz d) Repeated testing accuracy of internal resistance of Prismatic cell: ± 0.006mΩ
Standard Configurations
Open circuit voltage test and internal resistance test
Equipped with zeroing mechanism
(Master and standard resistance block)
Optional Configurations
Shell voltage testing; ambient temperature detection;instrument (customized)