CAPACITY GRADING INTEGRATED MACHINE FOR 4680 CYLINDRICAL CELL
Features
- Single-cell temperature detection, with high-precision temperature collection technology, excellent chamber temperature uniformity of ±2℃
- Automatic calibration design
- Compatible with cells of different heights and available for quick changeover
- Anomaly detection(polarity / tab contact resistance / loop contact resistance / ambient temperature / channel temperature / smoke / power shut-off protection)
- Diversified probe structures, adapted to the diversified cell electrode structures of different system
Basic Parameters
- Chamber Temperature Uniformity:±2 ℃
- Charging Efficiency:≥83%
- Discharging Efficiency:≥75%
- Chamber Channels:144/196/256CH
Standard Configurations
- Single channel temperature probe
- Multiple ambient temperature probes in the chamber, 2 and more smoke detections, high precision adjustable smoke sensors
- Energy feedback power modules
- Modular probe board assembly with back pull-out
- Triple protection from module, process,system perspective
Optional Configurations
- Intelligent series type power module
- PCS high voltage DC
- Water and gas integrated firefighting, aerosol firefighting
- Capacity temperature compensation
- Automatic wireless power module calibration tooling / Cable & wires sequence checking tooling / Probe cleaning
- Single-chamber temperature self-control technology
- Forced smoke exhaust